● Safety and Reliability
N+1/2N redundant design. The continuous power supply with back up battary guarantees stable IT equipment operation.
·Multi-stage automatic alarm function. Real-time system condition monitoring.
· Containment top panel can be opened by the fire system.
●Smart management
· Centralized monitoring platform makes us know the data center environment, power and temperature & humidity status in real-time.
· Powerful reporting capabilities.
· 365 days 7x24-hour unattended, remote monitoring. Minimize IT operation and maintenance costs.
●Energy-efficient
· Sealing hot or cold ventilation channels, greatly reduced the energy consumption.
· Inrow air conditioner close to heat source delivering air flow accurately to where desired.
· Efficient modular UPS.
· High density. A single cabinet supports a maximum 15 kW to meets various customer requirements.
●Quick Deployment
· Full integration of IT cabinet, UPS, battary, power distribution and precision cooling system.
· Modular components following international standards are quick to play within 7 days and greatly shorten the business on line cycle.
· Efficient modular UPS.
· Can be installed on a concrete floor, which greatly simplifies the corresponding engineering tasks.
Mode | IDM-16CS | IDM-20CS | IDM-16CB | IDM-20CB | IDM-16CT | IDM-20CT | IDM-16CF | IDM-20CF |
Structure and cabinets | ||||||||
Installation area(m²) | ≥24 | ≥30 | ≥24 | ≥30 | ≥24 | ≥30 | ≥24 | ≥30 |
Installation height(m) | 2.6 | |||||||
Cabinet size (W*D*H)mm |
600*1100*2000(42U) | |||||||
Power | ||||||||
Total IT capacity (KW) |
55 | 75 | 80 | 104 | 90 | 130 | 120 | 165 |
Redundant architecture |
N+X | |||||||
Power format | Input:380V/3P;Output:380V/3P | |||||||
UPS power(KVA) | 100 | 120 | 140 | 160 | 140 | 180 | 200 | 200 |
Backup time(min) | 10、15、30、60、120、240min | |||||||
Cooling | ||||||||
Redundant architecture |
N+1 | |||||||
Cooling Capacity (KW) |
23 | 25 | 23 | 40 | ||||
Width(mm) | 300 | 400 | 300 | 600 | ||||
Monitoring | ||||||||
Temperature and humidity sensors |
Sdandard configuration two,can local precision monitoring according to customer requirement |
|||||||
Smoke sensors | 2 | |||||||
Leak detection | Yes | |||||||
Camera | 2 | |||||||
UPS | Yes | |||||||
Power distribution monitoring | Yes | |||||||
AC monitoring | Yes | |||||||
KVM | Optional | |||||||
Notes | IDM product solutions can be customized depending on the number of cabinetspower densities power modes, different backup time,UPS,Air conditioning |