Industrial UPS-UID Family
100-800kVA
The UID series from 100 to 800 kVA are the Kstar UPS solution for installations requiring high energy efficiency and maximum power availability. These UPS provides maximum protection and power quality for data centres and industrial loads. The UPS has DSP (Digital Signal Processor) technology and provides true-line, double conversion power protection (in accordance with IEC EN 62040-3).
General Features
● Online double conversion
● Full DSP control
● High power factor
● Wide input adaptability
● Optimized battery management
● N+X parallel redundancy
● Strong overload capability
● Power walk in
● Generator mode
● Multi-protection
● EPO function
● User-friendly network management
Technical Specification
MODEL | UID100 | UID120 | UID160 | UID200 | UID300 | UID400 | UID500 | UID600 | UID800 | ||
Capacity (VA/Watts) |
100kVA / 90kW | 120kVA / 108kW | 160kVA / 144kW | 200kVA / 180kW | 300kVA / 270kW | 400kVA/ 360kW | 500kVA/ 450kW | 600kVA/ 540kW | 800kVA/ 720kW |
||
INPUT | |||||||||||
Operating voltage range |
380/400/415Vac (-25% / +20% ), (3Ph+N+PE) | ||||||||||
Operating frequency range |
50/60Hz(±5%) | ||||||||||
Power Factor | >0.97 (with filter) | ||||||||||
OUTPUT | |||||||||||
Output Voltage | 380/400/415Vac (±1%) | ||||||||||
Output frequency |
50/60Hz (±0.05%) | ||||||||||
Harmonic Distortion (THDv) |
<2% with linear load | ||||||||||
Crest factor | 3:1 (max) | ||||||||||
Efficiency | ≥92% | ≥92.5% | ≥93% | ≥93.5% | ≥94% | ||||||
BYPASS | |||||||||||
Rated voltage | 380/400/415Vac | ||||||||||
Rated frequency |
50/60Hz (auto-sensing) | ||||||||||
Voltage protection range |
Upper limit: +20% (+10%,+15%,+20% adjustable)Lower limit: -40% (-10%, -20%, -30%, -40% adjustable) | ||||||||||
Frequency protection range |
±10% (±2.5%, ±5%,±10%, ±20% adjustable) | ||||||||||
BATTERY | |||||||||||
Battery voltage |
384Vdc ( 360~408Vdc ) | 480Vdc | 600Vdc | ||||||||
SYSTEM FEATURES | |||||||||||
Transfer time | 0ms (Line mode →Battery mode) | ||||||||||
Overload | Load≤110%/60min ,≤125%/10min ,≤150%/1min,to Bypass | ||||||||||
LED display | Input, Inverter, Bypass, Battery, Output, Status | ||||||||||
LCD display | I/O voltage, frequency, power, power factor, battery voltage, current, battery status, load percentage, UPS status, history record, settings |
||||||||||
Communication interface | Dry contact, RS232, RS485, SNMP card (Optional) | ||||||||||
Optional | Harmonic filter, SNMP adapter, LBS cables, battery temperature sensor,Bypass current-sharing inductor | ||||||||||
ENVIRONMENT | |||||||||||
Operating Temperature |
0℃~40℃ | ||||||||||
Storage temperature |
-25~55℃ | ||||||||||
Humidity range |
0~95% (non-condensing) | ||||||||||
Altitude | <1500m | ||||||||||
Noise level | <65db | <70dB | |||||||||
PHYSICAL | |||||||||||
Dimension W×D×H (mm) |
890×775×1600(6P) 1515×830×1600(12P) |
1200×800×1600(6P) 1400×1000×1900(12P) |
1400×1000×1900(6P) 1640×1000×1900(12P) |
2580×1000×1900(500)12P 2800×1040×1900(600)12P |
3280×1040 ×1950(12P) | ||||||
Net weight (kg) |
625/1300 | 685/1450 | 1219/1774 | 1030/1715 | 1560/2395 | 1640/2510 | 3510 | 3950 | 4950 | ||
Shipping weight (kg) |
695/1370 | 755/1520 | 1349/1954 | 1130/1845 | 1690/2545 | 1770/2665 | 3730 | 4250 | 5245 | ||
STANDARDS | |||||||||||
Safety | IEC/EN62040-1;IEC/EN60950-1 | ||||||||||
Performance |
IEC 62040-3 | ||||||||||
EMC | IEC/EN62040-2;IEC 61000-2-2;IEC61000-4-2;IEC61000-4-3;IEC61000-4-4; IEC61000-4-5;IEC61000-4-6;IEC61000-4-8;IEC 61000-4-11; |