HPM
40-1000kVA
HPM series modular UPS is a scalable, modular UPS solution that combines the highest levels of reliability and felxiblity. It allows you to add capacity or redundancy and increase runtime as your business growth. The HPM’high power density design, small footprint and redundant control system make it an ideal solution for an array of data center, mission critical, and retail applications.Support ODM/OEM, contact:sales@kstar.com
General Features
●Adopting digital control design, and the control system is more reliable
● High input factor 0.99 and output factor 1.
● 3-level topology design, efficiency is up to 96%
● Support parallel expansion for cabinet, and parallel expansion is up to 4-6 cabinets.
● Batteries number of each group can be selected from 30 pieces to 50 pieces.
● With 7 inches (standard) and 10 inches (optional) colorful touch LCD screen
Technical Specification
Module Model | HPM3300E-RM-40 | HPM3300E-RM-50 | |||
Cabinet Model | HPM3300E-200/320/400 | HPM3300E-200/300/400/500/600/800/1000 | |||
Cabinet capacity (VA) | 200k~400k | 200k~1000k | |||
Module capacity (VA) | 40k | 50k | |||
Max. Number | 05/8/10 | 4/6/8/10/12/16/20 | |||
INPUT | |||||
Nominal voltage | 380/400/415Vac, (3Ph+N+PE) | ||||
Operating voltage range | 138~305Vacfor 40% Load; 305~485Vac for 100% Load; | ||||
Operating frequency range | 40Hz-70Hz | ||||
Power factor | ≥0.99 | ||||
Harmonic distortion (THDi) | ≤3% (100% linear load) | ||||
Bypass voltage range | Max. voltage:220V: +25% (optional+10%, +15%, +20% ); 230V: +20% (optional +10%, +15% ); 240V: +15% (optional +10%) Min. voltage: -45% (optional-10%, -15%, -20%, -30%) |
||||
Bypass Frequency range | Frequency protection range: ±10% | ||||
Power Walk In | Support | ||||
Generator input | Support | ||||
OUTPUT | |||||
Rated voltage | 380/400/415Vac, (3Ph+N+PE) | ||||
Power factor | 1 | ||||
Voltage regulation | ±1% | ||||
Output frequency | Line Mode | Synchronize with input, when the input frequency >±10%(±1%/±2%/±3%/±4%/±5% optional), output 50/60 (±0.1Hz) | |||
Bat. Mode | (50/60±0.1%)Hz | ||||
Crest factor | 0.125694444 | ||||
Harmonic distortion (THDv) | ≤1% with linear load; ≤3% with nonlinear load | ||||
Efficiency | up to 96% | ||||
BATTERY | |||||
Battery voltage | Optional Voltage: ±180/192/204/216/228/240/252/264/276/288/300Vdc(30/32/34/36/38/40/42/44/46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 36 pcs default, 36~50 pcs no power derating; 32~34 pcs output power factor 0.9; 30 pcs output power factor 0.8) |
||||
Power module charge current | 20A (Max.) | ||||
SYSTEM FEATURES | |||||
Transfer time | Utility to Battery : 0ms; Utility to bypass: 0ms | ||||
Overload | Line Mode | ≤110%, 60min; ≤125%, 10min; ≤150%,1min; to bypass.>150% Shut down Immediately. | |||
Bypass Mode | 135% overload for long term; >1000% overload for 100 ms | ||||
Overheat | Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately | ||||
Low battery voltage | Alarm and Switch off | ||||
Self-diagnostics | Upon Power On and Software Control | ||||
Backfeed | Support | ||||
EPO | Shut down UPS immediately (turn to bypass optional) | ||||
Battery | Advanced Battery Management | ||||
Noise suppression | Complies with EN62040-3 | ||||
Audible & Visual alarms | Line Failure, Battery Low, Overload, System Fault | ||||
Status LED & LCD display | Line Mode, Bypass Mode, Battery Low, Battery Fault, Overload & UPS Fault | ||||
Reading on the LCD display |
|
||||
Communication interface |
|
||||
ENVIRONMENTAL | |||||
Operating temperature | 0℃~40℃ | ||||
Storage temperature | -25℃~55℃ | ||||
Humidity range | 0~95% (non condensing) | ||||
Altitude | <1500m, derating required when >1500m | ||||
Noise level(from 1M distance) | <68dB | <73dB | |||
PHYSICAL | |||||
Dimension WxD×H (mm) | UPS cabinet (S / F) |
200/320kVA: 600×850×2000 400kVA: 1200×850×2000 |
200/300/400kVA: 600×850×2000 | ||
Power module | 440×620×130 | ||||
Net weight (kg) | UPS cabinet (S / F) |
210~460 | 200kVA: 240; 300kVA: 260; 400kVA: 290; 500kVA: 480; 600kVA: 540; 800kVA: 960; 1000kVA: 1050 |
||
Power module | 33 | 34 | |||
STANDARDS | |||||
Safety | IEC/EN62040-1, IEC/EN62477-1 | ||||
EMC | IEC/EN62040-2 (IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000- |