HPM330 0E-RT (10-50kVA)
10-50kVA
Building on the best-in-class reliability of the KSTAR UPS platform, the HPM330 0E-RT rack-mounted UPS provides a dependable and cost-effective power backup solution with a higher power density, a smaller footprint that makes it the ideal solution for distributed IT and edge computing environments.
General Features
● Double conversion online design
● Input power factor correction (PFC) technology
● input power factor up to 0.99
● Digital control process (DSP) makes the system more stable and reliable
● Parallel redundance function, max six in parallel
● LSB synchronization (40~50KVA).
● Battery pack can be common connection in parallel operation
● 30~50 pcs battery are settable
● Intelligent charging management
● LED+LCD display
● Self-diagnosis function
● EPO function
Technical Specification
MODEL | HPM3310-RT | HPM3315-RT | HPM3320-RT | HPM3330-RT | HPM3340-RT | HPM3350-RT | ||||||||
Capacity (VA/Watts) | 10k/10k | 15k/15k | 20k/20k |
30k/30k | 40k/40k |
50k/50k | ||||||||
INPUT | ||||||||||||||
Input&Output System | 3/3、3/1、1/1 , Support Double sources input | 3/3, Support Double sources input | ||||||||||||
Nominal Voltage | 380/400/415 (3Ph+N+PE) ; 220/230/240 (P-N) | 380/400/415 (3Ph+N+PE) | ||||||||||||
Operating voltage range | 208~485 | 138~485 | ||||||||||||
Operating frequency range | 40~70Hz | |||||||||||||
Power Factor | ≥0.99 | |||||||||||||
Harmonic distortion (THDi) | ≤3% (100% linear load) | |||||||||||||
Bypass input | ||||||||||||||
Normal voltage (Vac) | 3/3、3/1、1/1 , Support Double sources input | 3/3, Support Double sources input | ||||||||||||
Bypass voltage range | Max. voltage:220V: +25%(optional +10%,+15%,+20% ) ; 230V: +20%(optional +10%,+15% ) ; 240V: +15%(optional +10%) Min. voltage: -45% (optional -10%,-20%,-30%) |
|||||||||||||
Bypass Frequency range | Frequency protection range: ±10% | |||||||||||||
Generator input | Support | |||||||||||||
OUTPUT | ||||||||||||||
Output Voltage | 380/400/415Vac,(3Ph+N+PE) 220/230/240Vac,(P-N) |
380/400/415Vac (3Ph+N+PE) | ||||||||||||
Power Factor | 1.0 | |||||||||||||
Output frequency(Hz) | Line mode:Synchronize with input ;when input frequency >±10%%(±1%、±2%、±4%、±5% Optional, Output frequency 50×(1±0.1%)Hz Battery mode :(50/60±0.1%)Hz |
|||||||||||||
Waveform | Pure sine wave | |||||||||||||
Crest factor | 3:1 | |||||||||||||
Harmonic distortion(THDV) | ≤2%(100% linear load); ≤4% (100% non linear load) | |||||||||||||
Transfer Time(ms) | 0 Ms | |||||||||||||
Efficiency | UP to 95 | UP to 96 | ||||||||||||
Overload | ≤110% overload for 60 min; 125% overload for 10 min; ≤150% overload for 1 min | |||||||||||||
Bypass Mode | 135% overload for long term; >1000% overload for 100 ms | 135% overload for long term; >1000% overload for 100 ms | ||||||||||||
BATTERY | ||||||||||||||
Battery Voltage | For optional : Optional Voltage: ±180/192/204/216/228/ 240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/ 46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 30 pcs default, 36~50 pcs fully output ; 32~34 pcs Out put power factor 0.9; 30 pcs output power factor 0.8;) |
For optional : Optional Voltage: ±180/192/204/216/228/240 /252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/46/48/ 50pcs optional); 360Vdc~600Vdc (30~50 pcs, 36 pcs default, 36~50 pcs fully output ; 32~34 pcs Out put power factor 0.9; 30 pcs output power factor 0.8;) |
||||||||||||
Max charger current (A) | 18 | 20 | 18 | 20 | ||||||||||
Others | ||||||||||||||
Alarm function | Overload、utility abnormal、UPS fail、battery low voltage etc | |||||||||||||
Protection function | Short circuit、overload、overheat、battery low、output low voltage、fan fault、Anti-thunder | |||||||||||||
SYSTEM FEATURES | ||||||||||||||
Overload | Line Mode | Load≤110%: last 60min, ≤125%: last 10min, ≤150%: last 1min, ≥150% turn to bypass mode immediately | ||||||||||||
Bat. Mode | Load≤110%: last 10min, ≤125%: last 1min, ≤150%: last 5S, ≥150% shut down UPS immediately | |||||||||||||
Bypass Mode |
Breaker( Load < 125%, long-term operation) | |||||||||||||
Short circuit | Hold whole system | |||||||||||||
Communication interface | RS232, RS485, Parallel, Intelligent Slot(SNMP card/ Relay card(optional)), BMS (optional),EPO port, Output port, MAINTAIN-AUXSWS |
|||||||||||||
PHYSICAL | ||||||||||||||
Dimension W×H×D (mm) | 443x131(3U)x580 mm | 440x670x130(3U) | 440x800x175( 4U) | |||||||||||
Net Weight (kg) | 29 | 31 | 32 | 27 | 48 | 51 | ||||||||
ENVIRONMENT | ||||||||||||||
Operating temperature | 0~40℃ | |||||||||||||
Storage temperature | -25℃~60℃ | |||||||||||||
Humidity range | 0~95% (non-condensing) | |||||||||||||
Altitude | <1500m(when excess 1500m, according to GB/T 3859.2 to derating) | |||||||||||||
Noise Level | <55db | <58 | <62 | <65 | ||||||||||
STANDARDS | ||||||||||||||
Safety | IEC/EN62040-1,IEC/EN60950-1 | |||||||||||||
EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |