● Modular design, including power module, bypass module, monitoring module, can be easily integrated in MDC or customized cabinet.
● Width input voltage range, line voltage range is 138-485V,
● High input power factor, it is up to 0.99.
● Three level topology design, efficiency is up to 95.8%.
● THDi<3% (100% nonlinear load), THDi<5% (50% non-linear load)
● Sleeping mode to save power
● Support parallel expanded operation: maximum is 6 units
● Support sharing batteries for the UPS in parallel.
● Batteries number of each group can be selected from 30 pieces to 50 pieces.
● Large charging current can meet the requirement of long time backup.
● Output power factor is 1.0, UPS can supply power to 100% unbalance load.
● High adaptability for load, it can connect full inductive load or capacitive load.
● 7 inches colorful touch screen
● Support RS485, SNMP, Dry contact card , support RJ 45 interface and CAN interface.
● Support upgrade of CAN of power module inside of the cabinet.
Model | HPM3300E-60 | HPM3300E-120 | HPM3300E-150 | ||
UPS cabinet | 30k~60k / 30k~60k | 30k~120k / 30k~120 | 30k~150k / 30k~150k | ||
Max. Number | 2 | 4 | 5+1 | ||
Module | HPM3300E-RM-30 (30k / 30k) | ||||
Model | HPM3300E-50 | HPM3300E-100 | HPM3300E-150 | ||
UPS cabinet | 25k~50k / 25k~50k | 25k~100k / 25k~100k | 25k~150k / 25k~150k | ||
Max. Number | 2 | 4 | 5+1 | ||
Module | HPM3300E-RM-25 (25k / 25k) | ||||
Model | HPM3300E-40 | HPM3300E-80 | HPM3300E-120 | ||
UPS cabinet | 20k~40k / 20k~40k | 20k~80k / 20k~80k | 10k~120k / 10k~120k | ||
Max. Number | 2 | 4 | 5+1 | ||
Module | HPM3300E-RM-20 (20k / 20k) | ||||
Model | HPM3300E-30 | HPM3300E-60 | HPM3300E-90 | ||
UPS cabinet | 15k~30k / 15k~30k | 15k~60k / 15k~60k | 10k~90k / 10k~90k | ||
Max. Number | 2 | 4 | 5+1 | ||
Module | HPM3300E-RM-15 (15k / 15k) | ||||
Model | HPM3300E-20 | HPM3300E-40 | HPM3300E-60 | ||
UPS cabinet | 10k~20k / 10k~20k | 10k~40k / 10k~40k | 10k~60k / 10k~60k | ||
Max. Number | 2 | 4 | 5+1 | ||
Module | HPM3300E-RM-10 (10k / 10k) | ||||
INPUT | |||||
Nominal voltage | 380/400/415Vac, (3Ph+N+PE) | ||||
Operating voltage range | 138~305Vac for 40% Load; 305~485Vac for 100% Load; | ||||
Operating frequency range | 40Hz-70Hz | ||||
Power factor | ≥0.99 | ||||
Harmonic distortion (THDi) | 3% (100% linear load) | ||||
Bypass voltage range | Max. voltage:220V: +25%(optional +10%,+15%,+20% ) ; 230V: +20%(optional +10%,+15% ) ;240V: +15% (optional +10%) | ||||
Min. voltage: -45% (optional-10%, -20%,-30%) | |||||
Bypass Frequency range | Frequency protection range: ±10% | ||||
Generator input | Support | ||||
Backfeed protection | Support | ||||
OUTPUT | |||||
Rated voltage | 380/400/415Vac, (3Ph+N+PE) | ||||
Power factor | 1 | ||||
Voltage regulation | ±1% | ||||
Output | Line Mode | synchronize with input, when the input frequency >±10%(±1%/±2%/±3%/±4%/±5% optional),output 50/60(±0.1Hz) | |||
frequency | Bat. Mode | (50/60±0.1%)Hz | |||
Crest factor | 3:01 | ||||
Harmonic distortion (THD) | ≤2% with linear load; ≤4% with nonlinear load | ||||
Efficiency | UP to 95.8% | ||||
BATTERY | |||||
Optional Voltage:±180/192/204/216/228/240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/46/48/50pcs optional)360Vdc~600Vdc (30~50 pcs), 36 pcs default, 36~50 pcs fully output; 32~34 pcs output power factor 0.9; 30 pcs output power factor 0.8) | |||||
Battery voltage | |||||
Power module Charge Current | 18A (Max.) | ||||
UPS cabinet Max. Charge Current | 36A | 72A | 108A | ||
SYSTEM FEATURES | |||||
Transfer time | Utility to Battery : 0ms; Utility to bypass: 0ms | ||||
Overload | Line Mode | ≤110%,60min;≤125%,10min;≤150%,1min;to bypass.>150% Shut down Immediately. | |||
Bypass Mode | 135% overload for long term; >1000% overload for 100 ms | ||||
Overheat | Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately | ||||
Low battery voltage | Alarm and Switch off | ||||
Self-diagnostics | Upon Power On and Software Control | ||||
EPO(optional) | Shut down UPS immediately | ||||
Battery | Advanced Battery Management | ||||
Noise suppression | Complies with EN62040-3 | ||||
Audible & Visual alarms | Line Failure, Battery Low, Overload, System Fault | ||||
Status LED & LCD display | Line Mode, Bypass Mode, Battery Low, Battery Fault, Overload & UPS Fault | ||||
Reading on the LCD display | Input, Output, Battery, Command, Setting, Maintenance | ||||
Communication interface | CAN,RS485,Parallel, Dry contact port, Relay card(optional), SNMP card(optional),Battery temperature sensor(optional) | ||||
ENVIRONMENTAL | |||||
Operating temperature | 0℃~40℃ | ||||
Storage temperature | -25℃~55℃ | ||||
Humidity range | 0~95% (non condensing) | ||||
Altitude | < 1500m | ||||
Noise level(from 1M distance) | <58dB | <60dB | <62dB | ||
PHYSICAL | |||||
Dimension | |||||
W×HxD (mm) | UPS cabinet | 485×353(8U)×850 | 485×575(13U)×850 | 485×752(17U)×850 | |
440x86 (2U)x620 | |||||
Power module | |||||
Net weight (kg) | UPS cabinet | 142 | 153 | 295 | |
Power module | 21 | ||||
STANDARDS | |||||
Audible & Visual alarms | IEC/EN62040-1,IEC/EN60950-1 | ||||
EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4- 5,IEC61000-4-6,IEC61000-4-8 | ||||